The Design That Match The Doctor's Using Habits BestEfficient Workflow And Convenient& Fast PositioningFour-Way
Bearing: 250kg


The DF-211H is a US-FDA approved X-ray System has following features- ※ High Frequency Inverter Type X-ray Generator ※ Rotating Anode with Dual Focus ※ System has Control Panel with KVp Control and Automatic mAs and KV Controller ※ System Shows Anatomic Program on TFT display ※ System has. Automatic Over Load Protection for X-ray Tube to Ensure Long life time ※ System has Line Voltage Compensator and Fine Adjustment Facilities ※ Stationary X-ray tube support is integrated with the System ※ X-ray tube movement is Fully Counter Balance ※ Tube movement is Easy and Comfortable to Handle in all directions ※ System has Light Beam Collimator with Variable Exhaust Fan According to APR ※ System has Fully Radiolucent table top which does not absorb x ray and free form stain as well as table top is water proof and break resistance facilities ensure additional safety. ※ Table bucky uses movable grid and aluminum being used as interspaced material ※ Bucky is capable to travel the entire length of the table ※ Material of cassette tray is stainless steel ※ Auto centering of cassette with locking facilities and capable to acccommodate cassette size from 8" by 10" to 14" by 17" | |||||
![]() | Generator | Output Power: 50 kW, 65 kW or 80 Kw | |||
| High frequency output: 450kHz | |||||
| kVp Range: 40-150 KV | |||||
| mA Range: 10-630mA | |||||
| Exposure Timer Range: 1 msec to 6.3 sec (up to 10 sec optional) | |||||
| mAs Range (non-AEC): 630 mAs ( 1000 mAs range as an option) | |||||
| Anatomical Programs (APR): yes | |||||
| Options: AEC, DAP | |||||
| Input Phase / Voltage: 3 phase, AC380V±10%, 50±1Hz | |||||
![]() | X-ray Tube | Nominal focal spot value: 0.6mm (small focus)/1.2mm (large forcus) | |||
| Rotation speed (min-1): 2700rpm@50Hz, 3200rpm@60Hz | |||||
| Maximoa tube voltage: 150kV | |||||
| Maximum filament current: 500mA (small focus) / 1000mA(large focus) | |||||
| Anode Heat Content: 400kHU | |||||
| Max rating (0.1s) (kw): 22/55kW@50Hz, 23/60kW@60Hz | |||||
![]() | Radiographic table | Focal spot to tabletop/wall stand: 1100mm (min) | |||
| Stand | Tube vertical travel range:≧750mm | ||||
| Tube transverse travel range: ≧1250mm | |||||
| Tube rotation around table column: ±135°± 2° | |||||
| Tube rotation about the horizontal axis:+180° to -180°, locked at each 0°, 90°, 180°, 270° | |||||
| Taula | Standard table top size: L2200mm×W785mm | ||||
| Table height: 690mm | |||||
| Table top travel, longitudinal: 1000mm (min) | |||||
| Table top travel, transverse: 160mm (min) | |||||
| Gird | Size: 388mm×464mm (15"×18") | ||||
| R=10:1, f=100cm, N=40 line/cm | |||||
![]() | kolimadorea | Control method: Manual | |||
| Maximum X-ray field coverage range: 43cm*35cm | |||||
| The average brightness of the light field: >150lux | |||||
| Input power: 24V AC, 10A | |||||
![]() | Wall stand | Minimum focal spot height: 800mm | |||
| Vertical height: 2000mm | |||||
| Vertical travel range: 1000mm (min) | |||||
| Film size: 8"×10",10"×12",11"×14",14"×14", 12"×15", 14"× 17" | |||||
| Grid | Size: 388mm×464mm (15"× 18") | ||||
| R=10:1, f=180cm, N=40 line/cm | |||||
| |||||